TRANSACTIONS OF THE JAPANESE SOCIETY OF IRRIGATION, DRAINAGE AND RECLAMATION ENGINEERING, Volume 214, Page 43-53 (2001)
Proposal of the Equation to presume Drying Shrinkage Strain using for the
Early Age Crack Analysis in the Concrete Structure with Long One Direction
OGATA Hidehiko*, NONAKA Tsuguhiro** and HATTORI Kunio*
*Faculty of Agriculture, Tottori University, (101-4 Minami Koyama-cho, Tottori, 680-8553, JAPAN)
** Faculty of Life and Environmental Science, Shimane University (1060 Nishikawatsu, Matsue, 690-8504, JAPAN)
Abstract
@In the previous paper, an analytical condition to do the prediction of
a realistic early age crack in the RC box culvert was examined. However,
the examined analytical condition is not verified with two or more structures.
In this paper, the analytical condition which had been obtained by the
previous paper is reexamined by three RC box culverts where a structural
scale, a mixing of concrete, and the placing time were different. As a
result, the analytical result of early age crack in three RC box culverts
was different from the generative situation of measured crack, though the
result of obtaining by previous paper had been applied. This cause is relative
humidity used to presume drying shrinkage strain, relative humidity should
input not actual relative humidity but an opposite value on the equation
to presume drying shrinkage strain in JSCE. In this paper, a new equation
to presume drying shrinkage strain using for the early age crack analysis
in the concrete structure with long one direction was proposed.